APAR status
Closed as program error.
Error description
V10 HIPAA Compliance Check reports errors for some data content validated using Type 7 Business Rules with Pattern Match. The same data content is accepted in V9 HIPAA Compliance Check.
Local fix
ITXCQ - ITX00061556 MG / MG Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: Qualifier_Value content not being returned from hcsuv for some type 7 rules, making validation of these rules incorrect Platforms Affected: ALL
Problem conclusion
A previous fix to handle presence of $ in data being returned from HCSVU causes this issue. The original problem has been fixed so that <etx> is used instead of $ to delimit error records, as this value is not permitted in HIPAA data. Applies to: Healthcare Pack 10.1, 10.2 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH49860
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-09-28
Closed date
2022-10-18
Last modified date
2022-11-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
19 November 2022