A fix is available
APAR status
Closed as program error.
Error description
,USER= added to job card on JCL submitted by WRITEQ TD to INTRDR when nothing is coded for JOBUSERID on the TDQ definition. Also, when the JOB card spans two lines, sometimes CICS does not notice that USER=xxxxx is on the 2nd line of the job card. This prevents CICS from doing a surrogate check on that userid.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users * **************************************************************** * PROBLEM DESCRIPTION: Incorrect behaviour encountered when * * writing JCL to INTRDR via a WRITEQ TD. * **************************************************************** When JCL spanning more than one line is written to INTRDR by a WRITE TDQ, a superfluous ,USER= parameter is added erroneously to the JCL. Also the userid defined in the correctly submitted USER= parameter is not then subjected to a SURROGATE check when it should be.
Problem conclusion
Errors in DFHPSJP and DFHTDTM have been corrected to remove the problems with JCL submitted to INTRDR by WRITEQ TD
Temporary fix
Comments
APAR Information
APAR number
PH50916
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-15
Closed date
2023-01-27
Last modified date
2023-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90299
Modules/Macros
DFHPSJP DFHTDTM
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UI90299
UP23/01/28 P F301