A fix is available
APAR status
Closed as program error.
Error description
DR preparation program sets incorrect values for SPACE parameter on IDCAMS ALLOCATE command for OLDS data set. - Even though secondary allocation is not requested for the original OLDS data set, incorrect secondary allocation size is set. - If the original data set has been allocated at cylinder address X'8000' or higher, incorrect allocation size is set.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Recovery Expert users * **************************************************************** * PROBLEM DESCRIPTION: DR preparation program sets incorrect * * SPACE parameter for ALLOC command * **************************************************************** * RECOMMENDATION: Apply maintenance. * **************************************************************** DR preparation program sets incorrect values for SPACE parameter on IDCAMS ALLOCATE command for OLDS data set: - Even though secondary allocation is not requested for the original OLDS data set, incorrect secondary allocation size is set. - If the original data set has been allocated at cylinder address X'8000' or higher, incorrect allocation size is set. . This APAR also makes the following change: DR prep batch job has increased the JOB card input field on the ISPF panel from 65 to 72 bytes.
Problem conclusion
Program error has been fixed.
Temporary fix
Comments
APAR Information
APAR number
PH50108
Reported component name
IMS RECOVERY EX
Reported component ID
5655S9800
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-11
Closed date
2022-11-09
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83195
Modules/Macros
BSY#RBLK BSY#YARC BSY$BUTD BSY$DRCK BSY$OBLD BSY@YCRD BSY@YCRX
Fix information
Fixed component name
IMS RECOVERY EX
Fixed component ID
5655S9800
Applicable component levels
R220 PSY UI83195
UP22/11/11 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX8A7","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date: