Question & Answer
Question
How can this error be prevented?
Cause
LABEL: VIO_ALERT_EVENT
IDENTIFIER: 0FD4CF1A
Date/Time: Mon Nov 24 07:46:51 2015
Sequence Number: 13215
Machine Id: 00F939D04C00
Node Id: myvio
Class: O
Type: INFO
WPAR: Global
Resource Name: /var/vio/CM/DB
Description
Informational Message
Probable Causes
Asynchronous Event Occurred
Failure Causes
PROCESSOR
Recommended Actions
Check Detail Data
Detail Data
Alert Event Message
25b811
A File System alert event occurred on /var/vio/CM/DB. Low free space condition fixed. Free space is greater than 10%.
Diagnostic Analysis
Diagnostic Log sequence number: 38609
Resource tested: sysplanar0
Menu Number: 25B811
Description:
File System alert event occurred on /var/vio/CM/DB. Low free space condition fixed. Free space is greater than 10%.
LABEL: VIO_ALERT_EVENT
IDENTIFIER: 0FD4CF1A
...
Resource Name: /home/ios/CM/DB <<<
...
Detail Data
Alert Event Message
25b810
A File System alert event occurred on /home/ios/CM/DB. Free space is
less than 10%, or there was an error querying the filesystem.
Diagnostic Analysis
Diagnostic Log sequence number: 1444
Resource tested: sysplanar0
Menu Number: 25B810
Description:
IDENTIFIER: 0FD4CF1A
Date/Time: Mon Nov 24 07:46:51 2015
Sequence Number: 13215
Machine Id: 00F939D04C00
Node Id: myvio
Class: O
Type: INFO
WPAR: Global
Resource Name: /var/vio/CM/DB
Description
Informational Message
Probable Causes
Asynchronous Event Occurred
Failure Causes
PROCESSOR
Recommended Actions
Check Detail Data
Detail Data
Alert Event Message
25b811
A File System alert event occurred on /var/vio/CM/DB. Low free space condition fixed. Free space is greater than 10%.
Diagnostic Analysis
Diagnostic Log sequence number: 38609
Resource tested: sysplanar0
Menu Number: 25B811
Description:
File System alert event occurred on /var/vio/CM/DB. Low free space condition fixed. Free space is greater than 10%.
NOTE: At VIOS 2.2.3 and below, the filesystem alert is written to /var. Starting in VIOS 2.2.4 and above, the alert event was changed from /var to /home, i.e.
LABEL: VIO_ALERT_EVENT
IDENTIFIER: 0FD4CF1A
...
Resource Name: /home/ios/CM/DB <<<
...
Detail Data
Alert Event Message
25b810
A File System alert event occurred on /home/ios/CM/DB. Free space is
less than 10%, or there was an error querying the filesystem.
Diagnostic Analysis
Diagnostic Log sequence number: 1444
Resource tested: sysplanar0
Menu Number: 25B810
Description:
Answer
The error is a result of a failed attempt to query the size of the /var filesystem at VIOS 2.2.3 and below or /home filesystem starting at 2.2.4 and above. The query is a result of a change notification submitted to the vio_daemon resource daemon. This daemon is responsible for handling configuration database management changes, as well as handling shared storage pool (SSP) management when SSP is configured. Since vio_daemon is active by default, the filesystem alert may be logged on a VIOS where SSP is not implemented. The error may be triggered if vio_daemon cannot check the filesystem where the CM database is located (/var/vio/CM/DB at VIOS 2.2.3 and below or /home/ios/CM/DB at 2.2.4 or higher).
It is possible that at some point the filesystem may have hit 90% used or full, which would justify the alert.
When a filesystem is full, a J2_FS_FULL entry is logged in the errlog.
In some cases, the alert may be due to vio_daemon running out of memory.
Related APARs
Note: This APAR does NOT prevent the VIO_ALERT_EVENT. It simply updates the VIO_ALERT_EVENT's description label.
If your ioslevel is 2.2.3.0 - 2.2.3.52, update to 2.2.3.60 to obtain the APAR.
2.
IV84953 CM DAEMON RUNS OUT OF MEMORY AND THUS RESTARTS
VIOS levels affected: 2.2.3 and 2.2.4
For VIOS 2.2.3, the apar is included in 2.2.3.80 and higher.
For VIOS 2.2.4, the apar is included in 2.2.4.30, as well as 2.2.5.0 and above.
IBM recommends updating to a VIOS level containing the APAR.
This defect is also known to trigger the following HMC event with no VIO_ALERT_EVENT entry logged in VIOS errlog:
3.
IV89108 VIO_ALERT_EVENT CAUSED BY MEMORY LEAK IN VIO_CHGMGT DAEMON
Notice the Detail Data will include "errno=12"
It is possible that at some point the filesystem may have hit 90% used or full, which would justify the alert.
When a filesystem is full, a J2_FS_FULL entry is logged in the errlog.
- RECOMMENDATION
Check the errlog to see if /var or /home (depending on your ioslevel) is reported being full. As padmin, run:
- $ ioslevel
$ errlog |more
- $ df -g
If the filesystem is near 90% or more used, clean up the filesystem to avoid getting further alerts.
- $ ioslevel
In some cases, the alert may be due to vio_daemon running out of memory.
- Recommendation
See technote vio_daemon consuming high memory on VIOS for recovery.
Related APARs
1.
IV73000 INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK
Note: This APAR does NOT prevent the VIO_ALERT_EVENT. It simply updates the VIO_ALERT_EVENT's description label.
If your ioslevel is 2.2.3.0 - 2.2.3.52, update to 2.2.3.60 to obtain the APAR.
2.
IV84953 CM DAEMON RUNS OUT OF MEMORY AND THUS RESTARTS
VIOS levels affected: 2.2.3 and 2.2.4
For VIOS 2.2.3, the apar is included in 2.2.3.80 and higher.
For VIOS 2.2.4, the apar is included in 2.2.4.30, as well as 2.2.5.0 and above.
IBM recommends updating to a VIOS level containing the APAR.
This defect is also known to trigger the following HMC event with no VIO_ALERT_EVENT entry logged in VIOS errlog:
- Reference Code #25B810
System reference code #25B810
...
Reporting Primary Unit MTMS
9119-MME/104EB3P
...
Serviceable event text
File System alert event occurred on /home/ios/CM/DB. Free space is less than 10%, or there was an error querying the filesystem.
...
Reporting partition name
<VIOS partition name>
Partition host name
<VIOS hostname>
...
3.
IV89108 VIO_ALERT_EVENT CAUSED BY MEMORY LEAK IN VIO_CHGMGT DAEMON
Notice the Detail Data will include "errno=12"
- LABEL: VIO_ALERT_EVENT
IDENTIFIER: 0FD4CF1A
...
Resource Name: /home/ios/CM/DB
...
Detail Data
Alert Event Message
25b810
A File System alert event occurred on /home/ios/CM/DB. Error querying filesystem. errno=12
Diagnostic Analysis
Diagnostic Log sequence number: 164
Resource tested: sysplanar0
Menu Number: 25B810
Description:
File System alert event occurred on /home/ios/CM/DB. Error querying filesystem. errno=12
VIOS levels affected: 2.2.4 and 2.2.5
For VIOS 2.2.4, IV89108 is included in 2.2.4.40 and above.
For VIOS 2.2.5, IV89108 is included in 2.2.5.20 and above. - IBM recommends updating VIOS to an ioslevel containing the APAR.
- Note: if your ioslevel already includes IV84953 + IV89108, update to 2.2.6.10 or higher to obtain IV91485 and clear the error. Exception: If your current ioslevel is at or higher than 2.2.4.50 or 2.2.5.30, update the VIOS to 2.2.6.21 merged with 2.2.6.10 to obtain IV91485 and prevent the VIOS update from failing due to builddate requisite failures.
[{"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":null,"Platform":[{"code":"","label":"Other"}],"Version":"2.2.5;2.2.4;2.2.3;2.2.2;2.2.1;2.2.0","Edition":"Enterprise;Express;Standard","Line of Business":{"code":"LOB57","label":"Power"}}]
Was this topic helpful?
Document Information
Modified date:
19 February 2022
UID
isg3T1023036