Question
IDCAMS DCOLLECT gets IEC161I 009-0663 on HSM CDS
Cause
IDCAMS DCOLLECT gets IEC161I 009-0663 for DFHSM CDS data sets.
This is a known condition when running IDCAMS DCOLLECT against DFSMShsm CDS which are not in RLS mode.
ARCUTIL first tries to open the CDS in RLS mode, so the IEC161I RC009 is issued when this fails.
HSM then opens the CDS in NON RLS mode.
This is described in DFSMShsm Implementation and Customization Guide, Chapter " User Application Interfaces", under Choosing a Data Collection Method.
Customers whose HSM CDS are not in RLS mode may ignore this condition.
Answer
Customers whose HSM CDS is not in RLS mode may ignore this condition
Related Information
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG90","label":"z\/OS"},"Component":"5695DF103 - DFSMS ACCESS METHOD SERVICES","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"1.1;1.2;1.3;1.4;1.5;1.6;1.7;1.8;1.9;1.10;1.11;1.12;1.13;2.1;2.2;2.3;2.4","Edition":"","Line of Business":{"code":"LOB56","label":"Z HW"}}]