IBM Support

MSGIKJ56220i file SYSTSPRT NOT ALLOCATED, TOO MANY DATA SETS

Question & Answer


Question

IDCAMS batch job containing multiple DELETES and DEFINES in the same step fails with MSGIKJ56220i file SYSTSPRT NOT ALLOCATED, TOO MANY DATA SETS

Answer

Description:

IDCAMS batch job containing multiple DELETES and DEFINES in the same step fails with MSGIKJ56220i file SYSTSPRT NOT ALLOCATED, TOO MANY DATA SETS



Resolution:

Code DYNAMNBR on the JCL EXEC statement for example :

//DEFINE EXEC PGM=IDCAMS,REGION=0M,DYNAMNBR=10

The potential requirement for the DYNAMNBR parameter is documented in the DFSMS Access Method Services manual in the section titled ALLOCATE functional command syntax.




 

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG90","label":"z\/OS"},"Component":"5695DF103 - DFSMS ACCESS METHOD SERVICES","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"1.1;1.2;1.3;1.4;1.5;1.6;1.7;1.8;1.9;1.10;1.11;1.12;1.13;2.1;2.2;2.3;2.4","Edition":"","Line of Business":{"code":"LOB56","label":"Z HW"}}]

Historical Number

6130546

Document Information

Modified date:
24 May 2022

UID