IBM Support

Upgrading the HMC to Version 6.1.3

Troubleshooting


Problem

This document provides information about how to upgrade the HMC to Version 6.1.3.

Resolving The Problem


Document Description:
Prerequisites

HMC Version 4.1.1 and Version 4.2
If the HMC is at Version 4.2 and 4.1.1, it must be upgraded to Version 4.5 with required maintenance fix MH00454 before upgrading to Version 6.1.3. Use the instructions at: http://www14.software.ibm.com/webapp/set2/sas/f/hmcl/power5/download/v4x.html#45

HMC Version 4.3, 4.4 and 4.5
If the HMC is at Version 4.3, 4.4, or 4.5, use the special upgrade instruction in Rochester Support Center knowledgebase document N1018777, Upgrading the HMC from Version 4.3, 4.4, or 4.5. to Version 6.1.3. To link to document N1018777 immediately, click here.

HMC Version 5
Use the following instructions to upgrade the HMC from Version 5.x to Version 6.1.3 with the latest fixes.


Tab navigation

Using .iso images


Step 1: Download the HMC Version 6.1.2 Recovery .iso images HMC_Recovery_V6R1.2_1.iso and HMC_Recovery_V6R1.2_2.iso.
Step 2: Download HMC Version 6.1.3 Update images (MH01012): HMC_Update_V6R1.3_1.iso, HMC_Update_V6R1.3_2.iso, HMC_Update_V6R1.3_3.iso, and HMC_Update_V6R1.3_4.iso.
Step 3: Download the HMC Corrective Service Fixes MH01082.iso, MH01110.iso, MH01128.iso, MH01127.iso, and MH01168.iso.
Step 4: Burn recovery images to DVD-R.
Step 5: Burn HMC Version 6.1.3 Update images (MH01012) to CD-R.
Step 6: Burn HMC Version 6.1.3 corrective service fixes to CD-R.

Using CD/DVD


Step 1: Obtain the HMC Version 6.1.2 Recovery DVDs MH00919.
Step 2: Obtain HMC Version 6.1.3 Corrective Services update: MH01012.
Step 3: Obtain HMC Corrective Service Fixes: MH01082, MH01110, MH01128, MH01127, and MH01168.


Prerequisites
oBack up critical console data
As a safety precaution, IBM recommends that you back up critical console data before performing the upgrade. The backup can take several hours to complete.
Format DVD-RAM
a Expand Licensed Internal Code Maintenance, then click HMC Code Update.
b Format a DVD-RAM (it MUST be DVD-RAM media).
c Click Format Removable Media.
d Click Format DVD-RAM, then click OK.
e Click Backup/restore, then click Format.
Perform the backup
Expand Licensed Internal Code Maintenance > HMC Code Update > Backup Critical Console Data.
oVerify the internal modem compatibility with HMC 6.1.
To verify the internal modem compatibility with HMC 6.1, do the following:
1Determine the HMC model.

The internal modem compatibility determination applies to HMC model 7310-C04 and 7310-C05. If your HMC is any other model or if it does not contain an internal modem, proceed with the upgrade. Otherwise, continue with Step 2.
2Install the monkacpid efix.

The following corrective service packages have been created to determine the compatibility problem:

HMC Version 4: PTF MH00854 Click here to Download and burn the iso or order the CD
HMC Version 5: PTF MH00840 Click here to Download and burn the iso or order the CD
HMC Version 6.1.0 with NO FIXES only: PTF MH00841 Click here to Download and burn the iso or order the CD

To obtain the appropriate PTF, refer to the Corrective service page for your current HMC release: V4.x or V5.x.
3Run the monkacpid command in a restricted shell terminal at the HMC or from a remote client over SSH. The following is a sample output of the command, which is refreshed every 4 seconds:

Every 4s: /usr/bin/top -s -b -n 1 -p 3 Thu Sep 14 14:57:19 2006
top - 14:57:20 up 53 min, 2 users, load average: 0.17, 0.10, 0.08
Tasks: 1 total, 0 running, 1 sleeping, 0 stopped, 0 zombie
Cpu(s): 5.5% user, 1.0% system, 0.0% nice, 93.5% idle
Mem: 1022096k total, 919596k used, 102500k free, 32516k buffers
Swap: 2032212k total, 0k used, 2032212k free, 264288k cached

PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND
3 root 15 0 0 0 0 S 0.0 0.0 0:00.02 kacpid
4Verify the %CPU value. If the number in the %CPU column is greater than 10.0, contact IBM Hardware Support and refer to ECA 832 to order a replacement modem.
Upgrade Procedure (from Recovery Media)

You must perform a Save Upgrade Data task to preserve information on the HMC before upgrading to HMC 6.1.2. You must upgrade immediately after the Save Upgrade Data task. If you restart the HMC without doing the upgrade, you must log in and run the Save Upgrade Data task again before you perform the Upgrade.

Do the following at the HMC interface to upgrade your HMC by means of the Recovery DVDs.
1Select Licensed Internal Code Maintenance.
2Select HMC Code Update.
3Select Save Upgrade Data, and then insert a formatted DVD-RAM media into the DVD drive.
Note: The same DVD-RAM used for the backup critical console data can be used for the save upgrade data.
4Select the DVD drive, and then click Continue.
Note: Selecting "DVD Drive" saves the upgrade data to both the hard disk and the DVD-RAM. The DVD will contain a backup of the upgrade data stored on the hard drive. This backup can be used for recovering from an upgrade failure, if needed.
5Wait for the Save Upgrade Data task to complete. If the task fails, contact your next level of support before proceeding. If the Save Upgrade Data task is successful, you might still want to use the following optional procedure to verify the data:

a Open a restricted shell terminal as follows:

1 Right-click on the desktop area.
2 Select terminals.
3 Select rshterm.

b Run the command mount /media/cdrom.

c Run the command ls –l /media/cdrom.

d Verify that there are 5 tar files with the following names:

ACMSaveData.tar
RSCTSaveUpgrade.tar
SaveCCFWUpgradeData.tar
SaveHSCSystemUpgradeData.tar
SaveProfileDataUpgrade.tar

If any of these tar files are missing, contact your support representative.

e Run the command umount /media/cdrom.
6If the Save Upgrade Data task is successful, remove the DVD-RAM, insert the first V6.1.2 recovery media into the DVD-RAM drive, select the Console menu option, and then select Exit.
7Click Exit to display the Exit Hardware Management Console window.
8Click Reboot Console. The HMC reads the media in the DVD-RAM drive and displays the Install/Backup/Restore wizard window.
9Select Upgrade, and click Next.
10Select Upgrade from media, and click Next.
11Click Finish to start the Upgrade process.
12When prompted to insert the next media, remove the first media, and then insert the second media into the DVD-RAM drive.
13Select Option 1, and then press the Enter key to continue the upgrade.
14When the second media is complete, the following options are displayed:

1 Restore critical console data from DVD-RAM (Install)
2 Finish the installation

Select Option 2, Finish the installation, to complete the Upgrade.
15The HMC restores the data preserved by the Save Upgrade Data task.
The HMC then completes the booting process, during which you are prompted to select the language and keyboard mapping.
16At the Hardware Management Console login prompt, log in using your user id and password.
Accept the License Agreement for Machine Code twice to complete the HMC code update

Verifying a Successful Update

After the HMC is rebooted, do the following to verify that the HMC upgrade was successful:
1Select Help in the top menu bar.
2Select About the Hardware Management Console.
3On the About panel, verify the following information:

The Version is 6.
The Release is 1.2.
HMC Build level 20070201.1
","base_version=V6.1.2

Install the 6.1.3 Update

Important Note: HMC 6.1.X update packages consist of multiple CD updates. All update CDs must be installed.

At the HMC interface, do the following for each of the update CDs:
1Select Licensed Internal Code Maintenance.
2Select HMC Code Update.
3Select Install Corrective Service.
4Select Apply Corrective Service from removable media.
5Insert the first update CD into the DVD drive of the HMC.
6Press OK to start the update.
7When the first CD completes, the HMC displays a completion message and a check box to Install the next corrective service when you select OK. Remove the first CD, select Install the next corrective service when you select OK, and then click OK. The HMC returns to the Install Corrective Service screen.
8Insert the next CD, select the Apply Corrective Service from removable media radio button, and click OK to continue the update.
9Repeat Steps 7 and 8 for each remaining CD in the Update package.
10After the last CD completes, the HMC displays the following message:

The corrective service file was successfully applied. Wait until all tasks complete, and Manually reboot the HMC for the changes to take effect, or select the check box below.

Remove the last CD, select Automatically reboot the HMC when you select OK, and click OK.

Install the 6.1.3 Corrective Service Fixes

Install the 6.1.3 fixes in this order: MH01082, MH01110, MH01128, MH01127, and MH01168.
1Select Licensed Internal Code Maintenance.
2Select HMC Code Update.
3Select Install Corrective Service.
4Select Apply Corrective Service from removable media.
5Insert the Corrective Service CD into the DVD drive of the HMC.
6Press OK to start the update.
The HMC interface retrieves the update package from the CD and begins the installation process
7Reboot the HMC. When the installation completes, the HMC displays a completion message and a check box to reboot the HMC now. Ensure the reboot option is checked, and click OK.

Repeat Steps 1 through 7 for each remaining corrective service CD.

Verify successful update

After the HMC is rebooted, follow these steps to verify that the corrective service update was successful:
a Select Help in the top menu bar.
b Select About the Hardware Management Console.
c On the "About" splash panel, look for updated information about the update and fix you installed.

[{"Product":{"code":"SSB6AA","label":"Power System Hardware Management Console Physical Appliance"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":"HMC","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Historical Number

449632639

Document Information

Modified date:
22 September 2021

UID

nas8N1021575