APAR status
Closed as program error.
Error description
AFM gateway node deadlocks during the read operation if both prefetch and application tries to read the same file simultaneously.
Local fix
Problem summary
AFM gateway node deadlocks during the read operation if both prefetch and application tries to read the same file simultaneously.
Problem conclusion
This problem is fixed in 5.1.5 PTF 1 To see all Spectrum Scale APARs and their respective fix solutions refer to page https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: Fixed the deadlock during the read operation on AFM uncached file. Work around: None Problem trigger: Read operation on AFM uncached file Symptom: Deadlock Platforms affected: All Linux OS environments Functional Area affected: AFM Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ42361
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
515
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-09-12
Closed date
2022-09-12
Last modified date
2022-09-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
12 September 2022