IJ42147: IOSTAT -X NOT REPORTING FC/NPIV DISKS STATS. APPLIES TO AIX 7300-01

 

APAR status

  • Closed as program error.

Error description

  • iostat -X only reports for FC/NPIV attached disks:
    
    <Name>hdisk2</Name>
    <XferStats>
    
            <BusyPercent>0</BusyPercent>
            <KiloBytesRead>36010</KiloBytesRead>
            <KiloBytesWritten>6192</KiloBytesWritten>
            <BytesTransferred>43214848</BytesTransferred>
            <Transfers>2112</Transfers>
            <BytesRead>36874240</BytesRead>
            <BytesWritten>6340608</BytesWritten>
    </XferStats>
    
    <- missing everything else that we have in iostat -D:
    
    # iostat -D hdisk2
    
     xfer: %tm_act      bps      tps      bread      bwrtn
              0.0      6.3      0.0        5.4        0.9
     read:     rps  avgserv  minserv  maxserv   timeouts
              0.0      1.9      0.1     36.3           0
    write:     wps  avgserv  minserv  maxserv   timeouts
              0.0      0.3      0.3     21.4           0
    queue: avgtime  mintime  maxtime  avgwqsz    avgsqsz
              0.0      0.0      0.0      0.0        0.0
    

Local fix

  • N/A
    

Problem summary

  • iostat command with '-X' option does not print disk
    stats in case of FC/NPIV disks in XML format.
    

Problem conclusion

  • Iostat-related code added to
    report the FC/NPIV disk stats in
    XML format.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ42147

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2022-08-26

  • Closed date

    2022-08-26

  • Last modified date

    2023-11-13

  • APAR is sysrouted FROM one or more of the following:

    IJ39779

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

  • R730 PSY U890557

       UP22/11/14 I 1000

Fix is available