Flashes (Alerts)
Abstract
If a PowerVM-based system is managed by the Baseboard Management Controller (BMC) instead of the Hardware Management Console (HMC) and a platform dump is initiated and offloaded to a Linux logical partition (LPAR), then the platform dump does not get saved.
Content
Linux Releases Affected
SUSE Linux Enterprise Server (SLES) 15, Service Pack 3 and 4
Red Hat Enterprise Linux (RHEL) 8.6 and 9.0
IBM Systems Affected
All IBM Power Systems
Symptoms
This issue was caused by a regression introduced by CVE-2020-27777 that was meant to lock down RTAS calls from userspace exploit attempts. A special case was missing for the ibm,platform-dump RTAS call. As a result, offloaded dumps did not complete successfully. This issue is now corrected.
None.
Fix Outlook
SLES 15 SP4 (kernel 5.14.21-150400.24.11.1 and later)
RHEL 9.0
Linux Grub changes to support Maximum Processor during CAS Negotiation are being worked on and will be included in future releases.
I/O Device Impacted
None.