A fix is available
APAR status
Closed as program error.
Error description
A logical unload produces incorrect data (invalid or wrong value) instead of stopping to report that an invalid datetime value has been handled when evaluating an SQL expression. This occurs if all the following conditions are fulfilled: - the logical unload is processed in native mode - the logical unload specifies an SQL statement with expressions which evaluation requires handling a datetime value with an invalid year part of 0000 which occurs if: - case 1) the SQL expression specifies an invalid datetime constant such as in the following examples: TIMESTAMP('0000-01-01-00.00.00.000000') - case 2) the intermediary or final result of the SQL expression would produce a datetime value with a year part of 0000 such as in the following examples: TIMESTAMP('0001-01-01-00.00.00.000000') - 1 DAY or TIMESTAMP('0001-01-01-00.00.00.000000') - 5 YEAR while DB2 returns an SQL error when processing the same SQL expression: - case 1) DSNT408I SQLCODE = -181, ERROR: THE STRING REPRESENTATION OF A DATETIME VALUE IS NOT A VALID DATETIME VALUE - case 2) SQLCODE = -183, ERROR: AN ARITHMETIC OPERATION ON A DATE OR TIMESTAMP HAS A RESULT THAT IS NOT WITHIN THE VALID RANGE OF DATES
Local fix
Run the unload in SQ mode by specifying the DB2 FORCE option
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload * * for z/OS * **************************************************************** * PROBLEM DESCRIPTION: A logical unload produces incorrect * * data (invalid or wrong value) instead * * of stopping to report that an invalid * * datetime value has been handled when * * evaluating an SQL expression. * * * * This occurs if all the following * * conditions are fulfilled: * * - the logical unload is processed in * * native mode * * - the logical unload specifies an SQL * * statement with expressions which * * evaluation requires handling a * * datetime value with an invalid year * * part of 0000 which occurs if: * * - case 1) the SQL expression * * specifies an invalid datetime * * constant such as in the following * * examples: * * TIMESTAMP('0000-01-01-00.00.00.000000') * * - case 2) the intermediary or final * * result of the SQL expression * * would produce a datetime value * * with a year part of 0000 such as * * in the following examples: * * TIMESTAMP('0001-01-01-00.00.00.000000') * * - 1 DAY or * * TIMESTAMP('0001-01-01-00.00.00.000000') * * - 5 YEAR * * while DB2 returns an SQL error * * when processing the same SQL * * expression: * * - case 1) * * DSNT408I SQLCODE = -181, ERROR: THE * * STRING REPRESENTATION OF A DATETIME * * VALUE IS NOT A VALID DATETIME VALUE * * - case 2) * * SQLCODE = -183, ERROR: AN ARITHMETIC * * OPERATION ON A DATE OR TIMESTAMP HAS A * * RESULT THAT IS NOT WITHIN THE VALID * * RANGE OF DATES * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Incorrect unloaded data if SQL expression evaluation involves datetime value with non compliant year part.
Problem conclusion
Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH48523
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-08-08
Closed date
2022-11-01
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INZCHECK INZCRX10 INZCRXSM INZCRXSQ INZTPMEM INZUTILK
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
R510 PSY UI83089
UP22/11/05 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 December 2022