IBM Support

PH48233: BAQR1153W HTTP status code 400 is reported when a message greater than 4 KB in length is sent to an API endpoint.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • When sending a payload larger than 4096 bytes to an API
    endpoint, HTTP status code 400 is returned and the following
    message is reported
    
    BAQR1153W: HTTP status code 400 is returned in the response for
               the API operation (relativePath: <path>, method:
               <method>). Data transformation for the response is
               skipped. The response entity is returned directly.
    
    Additional search words: msgBAQR1153W msgBAQR1153 BAQR1153
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS Connect V3.0 OpenAPI 2 and *
    *                 OpenAPI 3 API requester.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: BAQR1153W HTTP status code 400 is       *
    *                      reported when a message greater than    *
    *                      4 KB in length is sent to an API        *
    *                      endpoint.                               *
    ****************************************************************
    The z/OS Connect API requester implementation automatically
    chunks data greater than 4 KB in length and adds a
    Transfer-Encoding field with a value of "chunked". If the API
    endpoint implementation does not support chunking, the request
    fails.
    

Problem conclusion

Temporary fix

Comments

  • z/OS Connect has been updated to add a new allowChunking
    attribute to the zosconnect_endpointConnection element to
    specify whether chunking is allowed to an API requester
    endpoint. Setting allowChunking="false" prevents chunking to the
    API endpoint. The default is allowChunking="true".
    
    The fix for this APAR is expected to be delivered by the PTF
    for z/OS Connect EE V3.0.66.0 (PH52022).
    

APAR Information

  • APAR number

    PH48233

  • Reported component name

    Z/OS CONNECT EE

  • Reported component ID

    5655CE300

  • Reported release

    000

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-07-26

  • Closed date

    2023-01-25

  • Last modified date

    2023-01-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    Z/OS CONNECT EE

  • Fixed component ID

    5655CE300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVVFY","label":"z\/OS Connect Enterprise Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.0"}]

Document Information

Modified date:
25 January 2023