A fix is available
APAR status
Closed as program error.
Error description
PH47445 CEMT Loop is in error
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users with PH47445 Applied. * **************************************************************** * PROBLEM DESCRIPTION: A CEMT INQUIRE may return NOT FOUND for * * a resource (eg. program, transaction * * etc). * **************************************************************** It is possible for a CEMT INQUIRE to return NOT FOUND for a resource such as a PROGRAM or TRANSACTION, should that resource not be alphabetically found on the first screen returned to the user's terminal.
Problem conclusion
UI81474 DFHEMT56 has been changed to ensure all resources are returned to the terminal which are subject to the INQUIRE command.
Temporary fix
Comments
APAR Information
APAR number
PH48267
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-27
Closed date
2022-08-22
Last modified date
2022-09-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI82043
Modules/Macros
DFHEMT56
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UI82043
UP22/09/01 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: