Troubleshooting
Problem
Users might experience up to 30mins delay when performing below actions:
- Registering new Gateway service with management server
- Adding new Gateway server to Gateway cluster
- When rebooting or restarting Gateway
These Logs entries can be seen in DataPower error report or gwd.logs:
[0x80e0084c][apic-gw-service][debug] apic-gw-service(default): tid(9248): lib:gateway-controller:apigateway:ApiGatewayConfigStatus: /drouter/local/abcd/config-sequence is NOT up-to-date: No log stat
First timeout after 10 minutes and start of retry (20 minute wait):
Second timeout after 20 minutes:
[0x88e001ef][apic-gw-service][error] apic-gw-service(default): tid(480): Timed out retrieving configuration status: ["config-sequence"]
[apic-gw-service][info] apic-gw-service(default): tid(480): After 600005 millisecond wait, configuration status is up to date: []
[apic-gw-service][debug] apic-gw-service(default): tid(480): lib:gateway-controller:apigateway:ApiGatewayConfigStatus: Attempting to modify timestamp for failed cfg : /drouter/local/preprod.api.inetpsa.com/config-sequence.cfg
[0x88e001f0][apic-gw-service][info] apic-gw-service(default): tid(480): Retrying retrieval of configuration status: ["config-sequence"]
Second timeout after 20 minutes:
[0x88e001f1][apic-gw-service][error] apic-gw-service(default): tid(480): Timed out on second attempt to retrieve configuration status: ["config-sequence"]
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB77","label":"Automation Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMNED","label":"IBM API Connect"},"ARM Category":[{"code":"a8m50000000L0rvAAC","label":"API Connect"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]
Log InLog in to view more of this document
This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.
Was this topic helpful?
Document Information
Modified date:
02 August 2022
UID
ibm16606985