IBM Support

PH47350: JCICS DTCFILE.C HAS A MISSING CHECK_EXEC_RC

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A JCICS RESETBR call is not returning a NOT FOUND condition.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: NOTFND response missing when using      *
    *                      KeyedFileBrowse.reset()                 *
    ****************************************************************
    A Java application attempts to use the KeyedFileBrowse JCICS
    class with method reset().  The passed in key does not exist
    within the file and a RecordNotFoundException is not returned
    as expected.
    
    This APAR also fixes a problem where the reset() method is
    called with a SearchType of EQUAL, however this is not processed
    correctly which may mean the browse is not repositioned as
    expected.
    

Problem conclusion

  • CICS updated to correctly check the command and return the
    relevant exception.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH47350

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-20

  • Closed date

    2022-07-19

  • Last modified date

    2022-08-02

  • APAR is sysrouted FROM one or more of the following:

    PH46127

  • APAR is sysrouted TO one or more of the following:

    UI81545

Modules/Macros

  • DFJ@H609 DFJDTCOE
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI81545

       UP22/07/21 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.