IBM Support

IJ40568: ECE POWER CONTROL FOR NVME DEVICES ON S390X ONLY IF ENABLED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • On s390x "mmvdisk simulate-dead", and "mmvdisk replace
    --prepare"
    commands are setting the device power off even though the
    power control stanza is not specified. An Err 5 can be seen.
    

Local fix

  • On "Pdisk state is missing" or err 5, power on
    the device before further processing.
    

Problem summary

  • On s390x "mmvdisk simulate-dead", and
    "mmvdisk replace --prepare"
    commands are setting the device power off even though the
    power control stanza is not specified. An Err 5 can be seen.
    

Problem conclusion

  • his problem is fixed in 5.1.4 PTF 1
    To see all Spectrum Scale APARs and
    their respective fix solutions refer to page
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_
    apars.html
    
    Benefits of the solution:
    With the fix the NVMe device will not be set to power off if
    the power control stanza is not specified in the EDF file,
    when "mmvdisk simulate-dead" or "mmvdisk replace --prepare"
    are issued.
    
    Work Around:
    On "Pdisk state is missing" or err 5, power on
    the device before further processing.
    Problem trigger:
    "mmvdisk simulate-dead", or "mmvdisk replace --prepare"
    Symptom: Error output/message
    Platforms affected: s390x-linux only
    Functional Area affected: ESS/GNR
    Customer Impact: High Importance
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ40568

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    514

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-15

  • Closed date

    2022-06-15

  • Last modified date

    2022-06-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: