Error description

  • ABSTRACT:
    AFM COS fileset hang because GW node is marked as
    inactive
    
    Error Description:
    When a node is specified as GW using "mmchnode --gateway"
    it's wrongly marked as inactive GW node, so
    access to all AFM filesets served by this GW node will
    hang. This could be recovered by restarting
    GPFS on this GW node
    
    Reported in:
    5.1.2 on all platforms
    
    Known Impact:
    All access to AFM filesets served by this GW node will
    hang.
    
    Verification steps:
    N/A
    
    Recovery action:
    restart GPFS on the newly assigned GW node.
    
    Local Fix:
    N/A
    

Local fix

Problem summary

  • Deadlock after changing the AFM gateway node using
    mmchnode command as the node change is not propagated
    correctly to all the nodes in the cluster.
    

Problem conclusion

  • This problem is fixed in 5.1.2 PTF 5
    To see all Spectrum Scale APARs and
    their respective fix solutions refer to page
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_
    apars.html
    
    
    Benefits of the solution:
    No more deadlock.
    
    Work around:
    Restart GPFS on gateway nodes
    Problem trigger:
    mmchnode --gateway/--nogateway
    Symptom:  Deadlock
    Platforms affected: All Linux OS environments
    Functional Area affected: AFM
    Customer Impact: High Importance
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ38093

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-02-25

  • Closed date

    2022-05-16

  • Last modified date

    2022-05-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"500","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
17 May 2022