IBM Support

OA63077: REVERT FIN OA61657. LOGREC ENTRY FOR ABEND0C4-11 IN IXLD2GLC AT HBB77C0

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4-10 or 11 at IXLD2GLC (HBB77C0) + 14DA could occur when
    undergoing the capture of SVCDUMP and SDATA=XESDATA was
    included.
    The translation exception storage could be due to the timing as
    it was freemain before trying to access it under the dump exit.
    
    ANALYSIS:
    ABEND0C4 occurs at IXLD2GLC (HBB77C0) + 14DA
    
    KNOWN IMPACT:
    IEA611I PARTIAL DUMP SDRSN = 00000000 00000000 00800000 00000000
    - Error occurred in an SDUMP global exit.
    Unnecessary logrec entry were seen.
    Due to the nature of the storage page involved, it could be a
    one time occurrance (ie Page freemained between the start of the
    dump and running in this IXLD2GLC) or repeated events (ie  If
    the same virtual page was seen as getmained but not backed by
    any real frame or aux frame any more).
    
    VERIFICATION STEPS:
    In the logrec symptom :
    TIME OF ERROR INFORMATION
      PSW: 07046001 80000000 00000000 0888E62C
      INSTRUCTION LENGTH: 04   INTERRUPT CODE: 0011
      FAILING INSTRUCTION TEXT: xxxxB223 0063 xx
      TRANSLATION EXCEPTION ADDRESS: 00000000_00A97801   <=*****
      EXCEPTION ACCESS IDENTIFICATION: 03
      BREAKING EVENT ADDRESS: 00000000_0888E5DC
      REGISTERS 0-7
      GR: 1BEE7CBC 00000FFF 00000000 00A97000 xxx
                     ********
    Instruction B2230063 and REG3 is the TEA.
    
    
    ADDITIONAL SYMPTOMS:
    ABEND0C4 PIC10 PIC11
    
    FINREVERSAL OA61657
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Installations exploiting basic or parallel sysplex at z/OS   *
    * V2R4 (HBB77C0) and above.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * MSGIEA611I or MSGIEA911E indicating partial dump with insert *
    * ERROR OCCURRED IN AN SDUMP GLOBAL EXIT or ERROR OCCURRED IN  *
    * AN SDUMP LOCAL EXIT, along with a LOGREC entry indicating an *
    * ABEND in an XCF or XES dump exit routine.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Install the applicable PTF on each system in the sysplex.  A *
    * rolling IPL is sufficient to activate the fix.               *
    ****************************************************************
    When accessing storage to be included in a dump, a dump exit may
    encounter a program check for a page that is not backed by real
    storage.  The dump exit routines that execute when a dump
    request specifies the SDATA COUPLE or XESDATA options or the
    STRDATA keyword fail to recognize this type of "expected" error
    and inappropriately record them in LOGREC and indicate a partial
    dump.
    
    SYSPLEXDS
    

Problem conclusion

  • The affected dump exit routines are modified to ignore expected
    errors and continue processing normally if they occur.  LOGREC
    entries are suppressed and the complete or partial status of the
    dump remains unchanged.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA63077

  • Reported component name

    CROSS SYS.EXT.S

  • Reported component ID

    5752SCIXL

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / SYSPLXDS / Xsystem

  • Submitted date

    2022-04-04

  • Closed date

    2023-01-24

  • Last modified date

    2023-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ92079 UJ92080

Modules/Macros

  • IXLD2GLC IXLD2LOC IXLD2GLG IXCD1DGR
    

Fix information

  • Fixed component name

    CROSS SYS.EXT.S

  • Fixed component ID

    5752SCIXL

Applicable component levels

  • R7C0 PSY UJ92079

       UP23/02/08 P F302  

  • R7D0 PSY UJ92080

       UP23/02/08 P F302  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7C0"}]

Document Information

Modified date:
01 March 2023