IBM Support

IJ38924: IO_URING OP_READ_FIXED ERROR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Issuing io_uring IORING_OP_READ_FIXED
    requests to read data into
    preallocated buffers fails with an error.
    

Local fix

  • When using io_uring, use IORING_OP_READ instead of
    IORING_OP_READ_FIXED. This would
    require changing the application
    issuing the requests and might come at a performance penalty.
    

Problem summary

  • Issuing io_uring IORING_OP_READ_FIXED
    requests to read data into
    preallocated buffers fails with an error.
    

Problem conclusion

  • This problem is fixed in 5.0.5 PTF 14
    To see all Spectrum Scale APARs and
    their respective fix solutions refer to page
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale
    apars.html
    
    Benefits of the solution:
    io_uring IORING_OP_READ_FIXED requests work as
    expected.
    
    Work Around:
    When using io_uring, use IORING_OP_READ instead of
    IORING_OP_READ_FIXED. This would
    require changing the application
    issuing the requests and might come at a performance penalty.
    
    Problem trigger:
    No pre-conditions are necessary.
    
    Symptom:
    IO error
    
    Platforms affected:  Linux Only
    
    Functional Area affected: All Scale Users
    
    Customer Impact: Suggested
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ38924

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-23

  • Closed date

    2022-03-23

  • Last modified date

    2022-03-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
24 March 2022