Error description
Given a parent directory with the SGID bit set, a file created with the SGID bit specified by a user who does not belong to the same group as the directory can still have the SGID bit set.
Local fix
Remove the SGID bit from the directory.
Problem summary
Given a parent directory with the SGID bit set, a file created with the SGID bit specified by a user who does not belong to the same group as the directory can still have the SGID bit set.
Problem conclusion
This problem is fixed in 5.1.2 PTF 4 To see all Spectrum Scale APARs and their respective fix solutions refer to page https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale apars.html Benefits of the solution: The SGID bit is not set for a file created in a directory with the SGID bit set. Work Around: Remove the SGID bit from the directory. Problem Trigger: Create a file with the SGID bit specified as a non-member group user in a directory with the SGID bit set. Symptom: Unexpected Results/Behavior Functional Area affected: All Scale Users Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ38786
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-22
Closed date
2022-03-22
Last modified date
2022-03-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date: