IBM Support

OA62955: CLARIFY NOTE FOR SET OPT= COMMAND IN MVS SYSTEM COMMANDS MANUAL

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • The z/OS MVS System Commands manual documents a Note under SET
    OPT=xx stating "you have to copy the whole parmlib member and
    make the change." It should be clarified that you can make a
    change to the currently active OPT member and activate it.
    
    The note is intended to explain that you can't have IEAOPT00 set
    at IPL time with a whole list of parameters, and then create a
    new parmlib with just one parameter to change just the one
    parameter. When you do a SET OPT=xx the code processes the
    entire OPT member and may reset some parameters back to their
    default if they are not in the new member just created.
    However, you can make a change to the currently active OPT
    member and do a SET OPT=xx against the active member.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of z/OS 2.4 (HBB77C0) and above.                   *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The documented description of command                        *
    * SET OPT=xx requires clarification.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The z/OS MVS System Commands manual documents a Note under SET
    OPT=xx stating "you have to copy the whole parmlib member and
    make the change." It should be clarified that you can make a
    change to the currently active OPT member and activate it.
    
    The note is intended to explain that you can't have IEAOPT00 set
    at IPL time with a whole list of parameters, and then create a
    new parmlib with just one parameter to change just the one
    parameter. When you do a SET OPT=xx the code processes the
    entire OPT member and may reset some parameters back to their
    default if they are not in the new member just created.
    However, you can make a change to the currently active OPT
    member and do a SET OPT=xx against the active member.
    

Problem conclusion

  • The documented description of command SET OPT=xx is clarified.
    
    Document Name:   z/OS MVS System Commands
    
    Document Number: SA38-0666-50
    
    +--- Location in Publication ---------------------------------+
    |                                                             |
    | Chapter:     MVS system commands reference                  |
    |                                                             |
    | Section:     SET command                                    |
    |                                                             |
    | Sub-section: Parameters                                     |
    |                                                             |
    +-------------------------------------------------------------+
    
     OPT=xx
    
        The two alphanumeric characters indicating the IEAOPTxx
        member of the logical parmlib that contains the new
        parameters SRM is to use.
    
     |  Note: For IEAOPTxx, only one member can be active at a
     |  time, and members are not concatenated when you activate
     |  a new member. For instance, if you want to change one of
     |  the parameters in the active IEAOPTxx member, you have
     |  two options:
     |
     |  o Update the parameter in the active IEAOPTxx member,
     |    and issue the SET OPT=xx command to activate the change.
     |
     |    - or -
     |
     |  o If you prefer to keep the active IEAOPTxx member intact,
     |    copy the entire contents of the active IEAOPTxx member
     |    to a new IEAOPTyy member and make your change in the
     |    IEAOPTyy member. Then, issue the SET OPT=yy command to
     |    activate the new member. Note that any parameters that
     |    were specifed in the original IEAOPTxx member that are
     |    not also specified in the new IEAOPTyy member might get
     |    reset to their default values.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA62955

  • Reported component name

    SRM - SYS RSRCE

  • Reported component ID

    5752SC1CX

  • Reported release

    7C0

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-09

  • Closed date

    2022-03-22

  • Last modified date

    2022-03-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Publications Referenced
SA38066650    

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7C0"}]

Document Information

Modified date:
23 March 2022