IBM Support

PH44912: ABENDS80A IPISIRUR + X'8A38' RUNNING THE IMS PA IRUR REPORT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1. ABEND80A in IPISIRUR obtaining 24-bit working storage areas
    for report processing.                                 S80A
    2. Internal Resource Usage Report (IRUR) IRLM System extract
       headings truncated.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.5       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend S80A/S878 IPISIRUR+8A38           *
    ****************************************************************
    Abend S80A in IPISIRUR obtaining 24-bit working storage area
    for report processing.
    

Problem conclusion

  • 1. The IMS PA IRUR report obtains working storage for each IMS
       system it reports on, this storage is currently in 24-bit
       storage below the line, this is changed to now be 31-bit
       storage above the line. In addition, buffer pool control
       blocks for input files currently in 24-bit storage are
       changed to use 31-bit storage and IMS PA Transit Engine
       queue manager control blocks residing in 24-bit storage are
       now moved to 31-bit storage.
    
    2. The IRLM System CSV extract headers may be truncated if the
       IRLM User extract is processed beforehand as they share a
       common set of headers and the default length was not reset
       before each report was processed.
    

Temporary fix

Comments

  • ×**** PE22/07/20 FIX IN ERROR. SEE APAR PH48137  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PH44912

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    450

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-15

  • Closed date

    2022-04-06

  • Last modified date

    2022-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI80032

Modules/Macros

  • IPI4QMGR IPISAPAR IPISIRUR IPISIRUX IPISMCOP IPISMERG
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R450 PSY UI80032

       UP22/04/09 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"450"}]

Document Information