IBM Support

IJ38518: AIX 7.3 CHANGED SOME PERFORMANCE TUNING COMMANDS' DEFAULT OUTPUT

 

APAR status

  • Closed as program error.

Error description

  • **************************************************************
    * USERS AFFECTED:
    * Systems running the AIX 7.3 Technology Level 0 with
    * any of the following filesets at or between the given levels:
    * MIN          MAX          FILESET
    * 7.3.0.0      7.3.0.0      bos.perf.tune
      **************************************************************
    * ERROR DESCRIPTION:
    * In AIX 7.3, some performance tuning commands' default output
    * changed when called with the -x option.
    * Live Update stats were added to default -x output for
    * commands such as "vmo".
    * This change in output may break some applications that
    * depend on it, such as Oracle RAC tuning pre-checks.
      **************************************************************
    * RECOMMENDATION:
    * Install APAR IJ38518.
    * Prior to fix availability, an interim fix is available from
    * either
    * ftp://aix.software.ibm.com/aix/ifixes/ij38518/
    * https://aix.software.ibm.com/aix/ifixes/ij38518/
    * Installation of the ifix does not require a reboot.
      **************************************************************
    

Local fix

Problem summary

  • scripts parsing -x output may fail
    

Problem conclusion

  • Tunable commands reports LU values when -K option is used with
    -L or -x options
    

Temporary fix

  •   *********
      * HIPER *
      *********
    

Comments

APAR Information

  • APAR number

    IJ38518

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Submitted date

    2022-03-11

  • Closed date

    2022-03-14

  • Last modified date

    2022-05-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ38577 U892358

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

  • R730 PSY U892358

       UP22/05/18 I 1000 Ž

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: