A fix is available
APAR status
Closed as program error.
Error description
SMF74IOS field is in microseconds but causes issues with additional calculations in the MVSPM_DEVICE_H table. SMF74IOS should be changed back to milliseconds. This will prevent calculations being done with a field in milliseconds and a field in microseconds.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM Z Decision Support and * * IBM Z Performance and Capacity Analytics * * users who use the * * z/OS Performance Management (MVSPM) * * component. * **************************************************************** * PROBLEM DESCRIPTION: The value of IOSQ_TIME in microseconds * * is causing inconsistent data values. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** IOSQ_TIME is being reported as microseconds instead of milliseconds.
Problem conclusion
The calculation of IOSQ time is changed to report in milliseconds instead of microseconds.
Temporary fix
Comments
APAR Information
APAR number
PH42643
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-12-08
Closed date
2022-02-22
Last modified date
2022-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI79434 UI79436
Modules/Macros
DRLTMPDE
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901"}]
Document Information
Modified date: