APAR status
Closed as program error.
Error description
On linux kernel 3.10 or higher, if the O_TRUNC flag is used and the file has been opened already, the O_TRUNC flag may be incorrectly ignored.
Local fix
Avoid using open() with O_CREAT and O_TRUNC flag
Problem summary
On linux kernel 3.10 or higher, if the O_TRUNC flag is used and the file has been opened already, the O_TRUNC flag may be incorrectly ignored.
Problem conclusion
This problem is fixed in 5.1.3 To see all Spectrum Scale APARs and their respective fix solutions refer to page https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: Ensure O_TRUNC flag is honored when used together with O_CREAT on open() calls. Work Around: Avoid using open() with O_CREAT and O_TRUNC flag Problem trigger: Using open() with O_CREAT and O_TRUNC flag on a system with linux kernel 3.10 or higher. Symptom: Unexpected Results/Behavior Platforms affected: ALL Linux OS environments Functional Area affected: All Scale Users Customer Impact: Critical
Temporary fix
Comments
APAR Information
APAR number
IJ37542
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-02-09
Closed date
2022-02-09
Last modified date
2022-03-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels