A fix is available
APAR status
Closed as program error.
Error description
Not all code paths were corrected by apar PH15741, it was discovered that this job creation or update may not correctly set up the bits in line with the new Safe Guard copy specifications which will cause the FCM program fail with I/O ERROR. MSG FRMT = 0, MSG NMBR = 4, REAS: 00 FCM Apar PH42291 - additional note A variation of this apar is still exposed to the issue and was recently reported. With PTF UI78254 applied on top of FCM 6.3.0 The F1 dataset may still have an extraneous character in the parms that is now re-purposed for a SafeGuarded setting and no longer valid for Flash Copy configurations: in DATASET *.TEMPC.JOBS PARM='FCEST,F1=102E59 the correct value can be found in the *.NEW.JOBS PARM='FCEST,F1=002E59 The JCLS are copied from *.TEMPC.JOBS by the D@SWITCH JCL into *.NEW.JOBS PARM='FCEST,F1=102E59 The first order byte needs to be set to 00 in order for the FlashCopy JOB to work correctly. Corrective action is not in plan at this time. Clients should consider migrating their FlashCopy Management to the new Technical direction which is a product called Copy Services Manager. As of Copy Services Manager 6.2.10 support is available for loading a Flash copy session into the native zOS environment using a session property "z/OS Management option". Please see the IBM Copy Services Manager 6.2.10 and up documentation in Knowledge Center for more details.
Local fix
Problem summary
The incremental option may still set the incorrect bit for FLC establish.
Problem conclusion
The correct bit order will be used during the job creation.
Temporary fix
Comments
APAR Information
APAR number
PH42291
Reported component name
CSM FCM
Reported component ID
5608FCM00
Reported release
63B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-22
Closed date
2021-11-24
Last modified date
2022-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78254
Modules/Macros
IWNRBJ20
Fix information
Fixed component name
CSM FCM
Fixed component ID
5608FCM00
Applicable component levels
R63B PSY UI78254
UP21/11/30 P F111
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"63B"}]
Document Information
Modified date:
28 September 2022