Error description

  • Converting a column to an identity column results in error
    ADB7955E in the DDL reader because the generated ALTER is
    missing a START WITH value. As a result, this message is
    received (for example):
    
    ADB2PA: The following statement could not be completely parsed :
    
    ADMIN ALTER TABLE >TABLE_NAME< REPLACE COLUMN "ID"
    DECIMAL(20, 0) NOT NULL GENERATED BY DEFAULT AS IDENTITY ( START
    WITH INCREMENT BY 1 MINVALUE 5001 MAXVALUE 99999 NO CYCLE CACHE
    50 NO ORDER)
    
    This is followed by an error message:
    
    ADB7955E ADBCDTS An ONCODE condition 612 has been detected from
    location MSG7954
    
    ADB7955E ADBCDTS Error: " ONCODE()=" 612" ONLOC()="MSG7954"
    ONLINE()=" 54494" ONOFFSET()=" 422" ONCONDCOND()="
    ONCONDID()=" 7"
    
    
    Keywords:  ONCODE612; msgadb7955e;
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    *                 and Db2 Object Comparison Tool for z/OS      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Errors ADB7955E and ONCODE 612 might    *
    *                      occur when trying to convert a column   *
    *                      to an identity column.                  *
    ****************************************************************
    Converting a column to an identity column might
    generate JCL that is missing a START WITH value. Executing this
    JCL can result in the following error:
    
    ADB7955E ADBCDTS An ONCODE condition 612 has been detected from
    location MSG7954ADB7955E ADBCDTS Error: " ONCODE()=" 612"
    ONLOC()="MSG7954" ONLINE()=" 54494" ONOFFSET()=" 422"
    ONCONDCOND()="ONCONDID()=" 7"
    
    Keywords: ONCODE612; msgadb7955e;
    

Problem conclusion

  • The problem has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH42270

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-11-22

  • Closed date

    2022-02-14

  • Last modified date

    2022-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79298

Modules/Macros

  • ADB27CMR
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI79298

       UP22/02/17 P F202

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.