A fix is available
APAR status
Closed as program error.
Error description
Diagnostic message is printed incorrectly
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 1- All SQL Capture users * * 2- All Capture users * **************************************************************** * PROBLEM DESCRIPTION: 1- Diagnostic message is printed * * incorrectly * * 2- QCapture ASN0569E error SIGSEGV * **************************************************************** 1- SQL Capture issued the diagnostic message 'Parameter index 87 is out of range' because SHRINK_MEMFULL is not a supported parameter. But this message is a diagnostic message and should be printed only if Capture is invoked with the DEBUG parameter. 2- QCapture abended with ASN0569E error after certain workload surges and large messages.
Problem conclusion
1- SQL Capture should print diagnostic messages only if it is started with the DEBUG parameter. 2- Fixed SIGSEGV problem and introduced two new CAPMON counters for troubleshooting ASNCLP was not updated. Function Level: 1140.103
Temporary fix
Comments
APAR Information
APAR number
PH42189
Reported component name
WS REPLICATION
Reported component ID
5655L8800
Reported release
B33
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-18
Closed date
2021-12-12
Last modified date
2022-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78502 UI78503 UI78504 UI78505
Modules/Macros
ASN2BASE ASN2SQLZ ASNACMD ASNADMSP ASNAPPLY ASNCAP ASNCATM ASNCCMD ASNCDINS ASNMCMD ASNMON ASNQACMD ASNQAPP ASNQCAP ASNQCCMD ASNQDEP ASNQEXRP ASNQMFMT ASNQSPIL ASNQSQLZ ASNQXFMT ASNRBASE ASNSQLCZ ASNTDIFF ASNTDSP ASNTRC
Fix information
Fixed component name
WS REPLICATION
Fixed component ID
5655L8800
Applicable component levels
RB33 PSY UI78502
UP21/12/14 P F112
RB34 PSY UI78503
UP21/12/15 P F112
RB35 PSY UI78504
UP21/12/14 P F112
RB36 PSY UI78505
UP21/12/15 P F112