PI23415: AUTHENTICITY ACCESS TO PROTECTED RESOURCES IS DENIED WHEN UPGRADING EXISTING APPLICATIONS TO WORKLIGHT STUDIO V6.2

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When you upgrade Worklight Studio, rebuild the project WAR and
    .wlapp, and deploy those files to the server, the existing
    clients that use authenticity stop working.
    

Local fix

  • 1. Import a copy of the Worklight project to Worklight Studio
    V6.2 and rename the project. The project is automatically
    upgraded to V6.2.
    2. Deploy the new WAR file and applications to the server in
    addition to the existing old WAR file version.
    3. Distribute the new applications.
    4. Block the old applications
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * End users running a client application that uses             *
    * authenticity, after the server application (wlapp) was       *
    * upgraded with a new studio and deployed with the same        *
    * application version.                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Applications access to authenticity protected resources will *
    * always be denied.                                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • For project WARs built with versions V6.2.0.x and later, apps
    and adapters that were built with any version 5.0.6.x and above
    (not later than the project WAR version itself)  can be
    deployed.
    In order to keep supporting the old applications, they should be
    deployed alongside the new applications.
    1.Import old project to the new version Worklight studio,
    application upgrade will be done automatically.
    2.Increment the upgraded applications versions.
    3.Deploy the new War file built with the new studio to the
    server.
    4.Deploy the new applications to the server alongside the old
    Worklight version built applications.
    5.Both applications work as expected. If you want to use the
    only the new ones, block the old ones and refer to the new ones
    for upgrade.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI23415

  • Reported component name

    WORKLIGHT CONSU

  • Reported component ID

    5725I4301

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-08-07

  • Closed date

    2014-08-26

  • Last modified date

    2014-08-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT CONSU

  • Fixed component ID

    5725I4301

Applicable component levels

  • R620 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021