Error description

  • When run AFM failover to a new target for a
    Single-Writer fileset, the fileset root's ACL might be
    changed to the same as home.  When the fileset is newly
    recreated at home, the default permission is 700.
    
    mmafmctl gpfs1 failover -j swfileset_nfs --new-target
    nfs://mapping1/gpfs/gpfs1/swfileset_nfs
    
    
    Reported In:
    Spectrum Scale 5.1.1 on RHEL7
    
    Known Impact:
    Permission denied unexpectedly
    
    Verification steps:
    Verify the ACL of fileset junction if it is as expected:
    mmgetacl <fileset junction>
    
    Recovery action:
    Fix the ACL manually to the correct value:
    mmeditacl <fileset junction>
    

Local fix

Problem summary

  • In SW case, fileset root inherits the metadata from home
    when failover is happened.If home fileset was recreate then
    metadata gets changed at cache with default value.
    

Problem conclusion

  • If SW case, existing metadata should not be modified for
    any files and fileset root as well.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ34398

  • Reported component name

    SPEC SCALE DME

  • Reported component ID

    5737F34AP

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-08-12

  • Closed date

    2021-10-14

  • Last modified date

    2021-10-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE DME

  • Fixed component ID

    5737F34AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
18 October 2021