APAR status
Closed as program error.
Error description
Upgrade from version prior to 5.1.1 then back out may cause CCR to stop working.
Local fix
Restore node using mmsdrrestore
Problem summary
Upgrade from version prior to 5.1.1 then back out may cause CCR to stop working.
Problem conclusion
This problem is fixed in 5.1.2 PTF 0 To see all Spectrum Scale APARs and their respective fix solutions refer to page https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: Before running mmchconfig release=LATEST, this fix allows a cluster to back out to a version prior to 5.1.1 without manually recreating key files or restoring a node. Work Around: Restore node using mmsdrrestore Problem trigger: The problem occurs when a cluster upgrade to GPFS version 5.1.1 or later then back out of the upgrade. This only happens if the cluster has authorized cluster or remote cluster defined. Symptom: Error output/message Cluster/File System Outage Upgrade/Install failure Platforms affected: All Functional Area affected: All Customer Impact: Suggested:
Temporary fix
Comments
APAR Information
APAR number
IJ35469
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-11
Closed date
2021-10-11
Last modified date
2021-10-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
13 October 2021