IBM Support

PH40905: OSC ENHANCEMENT TO IMPROVE PERFORMANCE OF THE ANALYZE PROCESS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This enhancement improves performance of the Analyze process for
    Online Structure Change utility.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Online Structure Change         *
    *                 utility in Fast Path Solution Pack Version   *
    *                 2 Release 1 (FMID: HAHQ210).                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR has enhanced the Online       *
    *                      Structure Change utility (OSC) to       *
    *                      provide a new ATASKCTL keyword.         *
    *                      Specifying an appropriate value on      *
    *                      this keyword can improve performance    *
    *                      of the internal ANALYZE job.            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    OSC has been enhanced to provide a new ATASKCTL keyword, so the
    users can specify the maximum number of input areas to be
    analyzed concurrently, which can help improve performance.
    Also, This APAR has addressed the following issues:
    1. Enables coexistence of logger exit routines for the Online
    Structure Change utility and for other OEM by using the IMS
    refreshable logger exit routine.
    2. The following internal jobs for the Online Structure Change
    utility have been modified.
    - xxxxxxD0, xxxxxxT0 and xxxxxxV0 have been modified to use
    DBRSYNC and STASYNC commands of IMS Tools Online System
    interface (TOSI) instead of IMS commands.
    - Incorrect parameter for the batch SPOC utility has been
    removed from xxxxxxP0, xxxxxxM0 and xxxxxxX0 jobs.
    3.Strengthens the check of apply records to avoid unexpected
    apply error.
    4.Outputs Base configuration report and OSC internal jobs
    scenario report even when the job abends.
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS Fast Path Solution Pack for z/OS Version 2 Release 1
    IMS High Performance Fast Path Utilities User's Guide
    (SC27-9536)
    Overview and Customization
    (GC27-9596)
    Refer to topic "What's new in IMS HP Fast Path Utilities"
    (https://www.ibm.com/docs/en/SSS8RM_2.1.0/fpxhua/topics/
    fpxovv-whatsnew.html) in IBM Documentation for doc changes
    associated with this APAR.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH40905

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2021-09-27

  • Closed date

    2022-01-31

  • Last modified date

    2022-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79127

Modules/Macros

  • HFP0TRM0 HFP0XCF0 HFP1CPI0 HFP1J2O0 HFP1J3A0 HFP1J3R0 HFP1J5A0
    HFP1J5C0 HFP1J5X0 HFP1J6V0 HFP1JCT0 HFP4APS0 HFP4APY0 HFP4DLI5
    HFP4DLIE HFP4DLN5 HFP4DLNE HFP4RND0 HFP4SDC0 HFP4SDD0 HFP4SIN0
    HFP4SOT0 HFP4SRT0 HFPCCDR0 HFPCDER0 HFPCTSK0 HFPFLGX0 HFPLCC10
    HFPLMAN0 HFPWMT00 HFPWMT40
    

Publications Referenced
SC27953605GC27959602   

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R210 PSY UI79127

       UP22/02/01 P F201  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]