IBM Support

VM66313: DIRMAINT CLONEDISK FLASHCOPY FAILS TO COPY ESE DISK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Attempting to clone a disk on an ESE volume using
    DirMaint CLONEDISK (non-persistent flashcopy) is failing.
    A CC of 0 from DirMaint is returned but no data is
    actually copied.
    
    CP APAR VM66565 has been opened to fix a problem which causes
    the flashcopy to fail.
    
    Based on old behavior from the original track space efficient
    support in Flashcopy, the NOCOPY bit on the flashcopy request is
    being set by default for space efficient target devices. This
    bit should no longer be set allowing the copy to occur.
    During the debug of the CP flachcopy problem it was
    determined the SEF indicator for Q V DETAILS output for DASD
    devices was only being set for old style trace space
    efficent disks. The fix for the missing SEF indicator will
    also be fixed by the CP APAR.
    
    
    This DirMaint APAR has been created to remove a check for the
    SEF indicator which would prevent DirMaint from falling back to
    DDR in case a flashcopy error copying to a targt space-efficient
    volume. Now that the SEF indicator will be correctly returned
    once the CP APAR is applied, the code in DirMaint is being
    removed to allow the failover to DDR for ESE in all cases.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DirMaint CLONEDISK command with *
    *                 Space Efficient disks.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    Attempting to clone a disk on an Extent Space Efficient (ESE)
    volume using the DirMaint CLONEDISK (non-persistent flashcopy)
    command does not appear to be working. A condition code
    of 0 from DirMaint is returned but no data is copied.
    During the processing of the FLASHCOPY to the ESE devices,
    the target device took on the behavior of a persistent
    flashcopy request with NOCOPY specified.
    
    To resolve the failure of the DirMaint CLONEDISK command
    to copy the data from the source disk to the target disk
    when ESE volumes are involved, z/VM CP APAR VM66565 must be
    applied.
    
    In addition, CP APAR VM66565 also corrects the output of the
    Query VIRTUAL DETAILS and Query VIRTUAL DASD DETAILS commands
    for Extent Space Efficient (ESE) disks. The code was not
    properly setting the 'SEF' indicator for ESE volumes.
    
    The DirMaint code in exec DVHDXD, used during CLONEDISK
    processing, is issuing QUERY VIRTUAL <vdev> DETAILS and
    looking for the 'SEF' keyword to determine whether or not
    a DDR failover should occur. Since the command was never
    emitting the 'SEF' keyword, the DDR failover was not allowed.
    With the update for APAR VM66565, it is possible DirMaint will
    parse the output, find the 'SEF' keyword and send back an error
    message when DirMaint should instead be ignoring the keyword
    and allowing a DDR failover for the ESE device.
    

Problem conclusion

  • The DirMaint DVHDXD EXEC has been updated to remove the QUERY
    VIRTUAL <vdev> DETAILS command and the code parsing the results
    for the 'SEF' keywork. This will allow DDR failover for Extent
    Space Efficient (ESE) devices.
    

Temporary fix

Comments

APAR Information

  • APAR number

    VM66313

  • Reported component name

    IBM DIRMAINT-VM

  • Reported component ID

    5749DVH00

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-17

  • Closed date

    2021-10-13

  • Last modified date

    2024-11-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UV99406 UV99407

Modules/Macros

  • DVHDXD
    

Fix information

  • Fixed component name

    IBM DIRMAINT-VM

  • Fixed component ID

    5749DVH00

Applicable component levels

  • R710 PSY UV99406

       UP21/10/27 I 1000

  • R720 PSY UV99407

       UP21/10/27 P 2401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"710"}]

Document Information

Modified date: