A fix is available
APAR status
Closed as new function.
Error description
This enhancement enables Online Structure Change utility to capture and apply FLD calls issued by the application. This enhancement is being implemented as a result of RFE requirement 148221.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Online Structure Change * * utility in Fast Path Solution Pack Version * * 2 Release 1 (FMID: HAHQ210). * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables Online Structure * * Change utility (OSC) to support the * * FLD call. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** With this APAR, OSC is able to capture and apply the FLD calls that are being issued during the OSC process when PRESTOP=YES is specified. This enhancement is being implemented as a result of RFE requirement 148221. Also, This APAR has changed OSC to continue processing instead of ending abnormally when there are uncommitted apply records. ======================== = DOCUMENTATION CHANGE = ======================== IMS Fast Path Solution Pack for z/OS Version 2 Release 1 IMS High Performance Fast Path Utilities User's Guide (SC27-9536) Refer to topic "What's new in IMS HP Fast Path Utilities" (https://www.ibm.com/docs/en/SSS8RM_2.1.0/fpxhua/topics/ fpxovv-whatsnew.html) in IBM Documentation for doc changes associated with this APAR.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH40613
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2021-09-14
Closed date
2022-03-02
Last modified date
2022-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI79526
Modules/Macros
HFP0TRM0 HFP1CIT0 HFP1JCC0 HFP1JCL0 HFP1RCN0 HFP3IOF5 HFP3IOFE HFP4API0 HFP4APS0 HFP4DLI5 HFP4DLIE HFP4DLN5 HFP4DLNE HFP4SOT0 HFP4SSA0 HFPCCDR0 HFPCDER0 HFPCPY45 HFPCPY4E HFPLAPY0 HFPLCC30 HFPLIJS0 HFPUROB0 HFPWMT40
| SC27953606 |
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R210 PSY UI79526
UP22/03/04 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.