A fix is available
APAR status
Closed as new function.
Error description
The new function is automatic backup for IMS directory, staging, and bootstrap data sets at every successful IMPORT DEFN SOURCE(CATALOG) command. . This APAR is the solution for RFE 147776.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM IMS Administration Tool for * * z/OS (FMID=HALC110) * **************************************************************** * PROBLEM DESCRIPTION: IMS directory/BSDS backup enhancement. * * Automatic backup (Auto Backup) is * * supported. By enabling automatic * * backup, a backup of the IMS directory * * is taken after a successful completion * * of the IMPORT DEFN command. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** IMS directory/BSDS backup enhancement. Automatic backup (Auto Backup) is supported. By enabling automatic backup, a backup of the IMS directory is taken after a successful completion of the IMPORT DEFN command. Also, the naming rules for the backup data set are changed as follows: - IMS ID is added to the data set name. - The maximum number of characters for the high-level qualifier (HLQ) is changed from 32 to 27. The enhancement is being implemented as a result of RFE 147776. ======================== = ACTION AFTER APPLY = ======================== After the PTF of this APAR PH38517 is applied, do the following tasks: - Copy the ATYOPST0 module from smphlq.SATYLOAD to CUSTLOAD, and issue BPE REFRESH USEREXIT command. ATYOPST0 is the part of the output type OM exit, and it is changed by the PTF. ATYOPST0 is included in the CUSTLOAD data set that was created by Tools Base SETUP. The CUSTLOAD is specified to the OM region STEPLIB. You need to copy and refresh ATYOPST0 to enable the auto backup of IMS Directory/BSDS function. - Change the high-level qualifier (HLQ) of IMS Directory/BSDS backup data set. The maximum number of characters for HLQ is changed from 32 to 27 by the PTF. If you defined the HLQ over 27 characters, change the HLQ. ======================== = DOCUMENTATION CHANGE = ======================== IMS Administration Tool for z/OS Version 1 Release 1 User's Guide and Reference (SC27-9011) is updated. Refer to topic "What's new in IMS Administration Tool" (https://www.ibm.com/docs/en/ims-admintool/1.1?topic=overview -whats-new-in-ims-administration-tool) in IBM Documentation for doc changes associated with this APAR.
Problem conclusion
IMSMGDACBS/K
Temporary fix
Comments
APAR Information
APAR number
PH38517
Reported component name
IMS ADMIN TOOL
Reported component ID
5655CAT00
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2021-06-28
Closed date
2021-08-31
Last modified date
2024-12-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76962
Modules/Macros
ATY#CLNT ATY#EMSG ATY#MENU ATY$APRQ ATY$M510 ATY$M520 ATY$M530 ATY$M5S0 ATY$SDBK ATY@IMSI ATY@OBJU ATY@OPT ATY@PROD ATY@SKEL ATYHM500 ATYHM510 ATYHM52A ATYHM52Y ATYHM530 ATYHM5S0 ATYLINK ATYM05 ATYOPST0 ATYPM510 ATYPM52A ATYPM52Y ATYPM530 ATYPM53S ATYPM5S0
| SC27901107 |
Fix information
Fixed component name
IMS ADMIN TOOL
Fixed component ID
5655CAT00
Applicable component levels
R110 PSY UI76962
UP21/09/02 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCD9F6","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date: