A fix is available
APAR status
Closed as program error.
Error description
Customers with NVMe device on VIOS may see error from PowerVC while attempting to create VM which prevents the deployment of a VM. used by: org.xml.sax.SAXParseException: cvc-enumeration-valid: Value '' is not facet-valid with respect to enumeration '[ONLINE, STOPPED, FAILED, MISSING]'. It must be a value from the enumeration. at org.apache.xerces.util.ErrorHandlerWrapper.createSAXParse Exception(Unknown Source) at org.apache.xerces.util.ErrorHandlerWrapper.error(Unknown Source)
Local fix
Problem may be resolved by rebooting VIOS-es.
Problem summary
Sometimes VIOS CM can report null value for PV state to HMC or PowerVC. This will cause an error.
Problem conclusion
Change to return STOPPED instead of null, and add more logs to understand what's leading to this.
Temporary fix
Comments
APAR Information
APAR number
IJ33737
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2021-07-13
Closed date
2021-07-13
Last modified date
2021-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
R720 PSY U874968
UP21/08/30 I 1000
PTF to Fileset Mapping
U874968 devices.vtdev.scsi.rte 7.2.5.100