APAR status
Closed as program error.
Error description
The PASSWORD MISSING error occurs because of a CDC bug when dmts64 returns the connection data to the utility so it can include the user name in the error message. We don't want to include the password in this message, so it is erased. The bug is the password was being erased directly in the connection info object that is used by the instance when creating new connections. So the password is missing for all subsequent connection attempts. The fix is to make a copy of the connection info before erasing the password and the erase the password in the copy and return the copy along with the error message.
Local fix
A) Don't run any target-side CDC utilities. There aren't very many - dmchangetablestate, dmset, and dmsupportinfo are the main ones B) Stop and restart the CDC instance when the Db2Wh connection failure happens. This will force CDC to re-obtain the user name and password from the secret store on disk.
Problem summary
**************************************************************** * USERS AFFECTED: * * This issue might affect you if you are using IDR * * 11.4.0.3-5596 or older as a target engine and you use CDC * * command line utilities with that engine. * **************************************************************** * PROBLEM DESCRIPTION: * * The problem occurs if you run a command line utility, and * * for some reason the utility is not able to connect to the * * database (for example, if the database rejects the * * connection request). Any new connection that the CDC engine * * tries to create will then fail until you restart the CDC * * engine. * **************************************************************** * RECOMMENDATION: * * Upgrade to IDR 11.4.0.4-5599 or newer. * ****************************************************************
Problem conclusion
Upgrading to IDR 11.4.0.4-5599 or newer resolves the issue.
Temporary fix
Comments
APAR Information
APAR number
JR63857
Reported component name
IS CDC DB2 LUW
Reported component ID
5725E30DL
Reported release
B40
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-30
Closed date
2021-08-16
Last modified date
2021-08-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
IS CDC DB2 LUW
Fixed component ID
5725E30DL
Applicable component levels
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTRGZ","label":"InfoSphere Data Replication"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B40"}]
Document Information
Modified date: