Question & Answer
Question
Answer
IBM Storwize V5030 and FlashSystem 50xx Clustering
The following table illustrates which combinations of Storwize V5030 and FlashSystem 50xx control enclosures can be clustered together.
The value in each cell indicates the maximum number of control enclosures supported in a clustered system.
Product | V5030 | V5030E | FS5030 | FS5035 | FS5045 | |
---|---|---|---|---|---|---|
MTM | 2078-312 2078-324 |
2072-312 2072-324 |
2072-3H2 2072-3H4 |
2072-3N2 2072-3N4 |
4680-3P2 4680-3P4 |
|
V5030 | 2078-312/324 | 2 | ||||
V5030E | 2072-312/324 | 2 | 2 | 2 | ||
FS5030 | 2072-3H2/3H4 | 2 | 2 | 2 | ||
FS5035 | 2072-3N2/3N4 | 2 | 2 | 2 | ||
FS5045 | 4680-3P2/3P4 | 2 |
IBM Storwize V5100 and FlashSystem 5x00 Clustering
The following table illustrates which combinations of Storwize V5100 and FlashSystem 5x00 control enclosures can be clustered together.
The value in each cell indicates the maximum number of control enclosures supported in a clustered system.
Product | V5100 | FS5100 | FS5200 | |
---|---|---|---|---|
MTM | 2078-424 2078-AF4 |
2077-4H4 | 4662-6H2 | |
V5100 | 2078-424/AF4 | 2 | 2 | |
FS5100 | 2077-4H4 | 2 | 2 | |
FS5200 | 4662-6H2 | 4 |
IBM Storwize V7000, FlashSystem 7200, 7300, 9100 and 9200 Clustering
The following table illustrates which combinations of Storwize V7000, FlashSystem 7200, 7300, 9100 and 9200 control enclosures can be clustered together.
It includes an indication of the final/terminal code level for some systems and the minimum supported code level for other combinations.
The value in each cell indicates the maximum number of control enclosures supported in a clustered system.
Product | V7000 | V7000 Gen2 | V7000 Gen2+ | V7000 Gen3 | FS7200 | FS7300 | FS9110 | FS9150 | FS9200 | |
---|---|---|---|---|---|---|---|---|---|---|
MTM | 2076-112/124 2076-312/324 |
2076-524 | 2076-624 | 2076-724 |
2076-824
4664-824
|
4657-924 |
9848-AF7
9848-AF8
|
9848-AF8 |
9848-AG8
4666-AG8
|
|
Terminal Level |
7.8.1 | 8.4.0 | 8.4.0 | 8.5.0 | ||||||
Minimum Supported Level |
7.8.1 | 8.2.0 | 8.3.1 | 8.5.0 | 8.2.0 | 8.2.0 | 8.3.1 | |||
V7000 | 2076-112/124 2076-312/324 |
4 | 4 | 4 | ||||||
V7000 Gen2 | 2076-524 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
V7000 Gen2+ | 2076-624 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
V7000 Gen3 | 2076-724 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | ||
FS7200 |
2076-824
4664-824
|
4 | 4 | 4 | 4 | 4 | 4 | 4 | ||
FS7300 |
4657-924
|
4 | ||||||||
FS9110 | 9848-AF7/AF8 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | ||
FS9150 | 9848-AF8 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | ||
FS9200 |
9846-AG8
4666-AG8
|
4 | 4 | 4 | 4 | 4 | 4 | 4 |
IBM FlashSystem 9500 Clustering
The following table illustrates which combinations of FlashSystem 9500 control enclosures can be clustered together.
The value in each cell indicates the maximum number of control enclosures supported in a clustered system.
Product | FS9500 | FS9500 | |
---|---|---|---|
MTM | 4666-AH8 | 4983-AH8 | |
FS9500 |
4666-AH8
|
2*
|
|
FS9500 | 4983-AH8 | 2* |
* More than two FlashSystem 9500 control enclosures can be supported in a system with an approved SCORE request. All FlashSystem 9500 control enclosures in a system must be the same machine type and model (MTM).
Was this topic helpful?
Document Information
Modified date:
24 July 2023
UID
ibm16469491