A fix is available
APAR status
Closed as program error.
Error description
**************************************************************** * USERS AFFECTED: * Systems running the 7200-05 Technology Level with * any of the following filesets at or between the given levels: * MIN MAX FILESET * 7.2.5.1 7.2.5.2 bos.liveupdate.rte **************************************************************** * PROBLEM DESCRIPTION: * When running tcpdump after Live Update, tcpdump fails and * prints * tcpdump: BIOCSETIF: lo0: No such device or address **************************************************************** * RECOMMENDATION: * Install APAR IJ32311. ****************************************************************
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * Systems running the 7200-05 Technology Level with * any of the following filesets at or between the given levels: * MIN MAX FILESET * 7.2.5.1 7.2.5.2 bos.liveupdate.rte **************************************************************** * PROBLEM DESCRIPTION: * When running tcpdump after Live Update, tcpdump fails and * prints * tcpdump: BIOCSETIF: lo0: No such device or address **************************************************************** * RECOMMENDATION: * Install APAR IJ32311. ****************************************************************
Problem conclusion
Change the signal sent to the iptrace process started by Live Update to one that iptrace catches, so iptrace can clean up.
Temporary fix
Comments
7200-04 - use AIX APAR IJ31368 7200-05 - use AIX APAR IJ32311
APAR Information
APAR number
IJ32311
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Submitted date
2021-04-26
Closed date
2021-04-26
Last modified date
2021-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
R720 PSY U874988
UP21/08/30 I 1000
PTF to Fileset Mapping
U874988 bos.liveupdate.rte 7.2.5.100