IJ31785: MMHEALTH INODE_HIGH_ERROR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • mmhealth has issues with high inode consumption
    

Local fix

  • If the filesystem contains multiple
    filesets (even the root filesystem) then check
    if any of them exceeds the defined
    limits and fix this issue.
    Use mmdf and mmlsfileset commands
    for more diagnostic.
    

Problem summary

  • mmhealth has issues with high inode consumption
    

Problem conclusion

  • Benefits of the solution:
    Give more hints how to investigate
    high inode or pool storage warnings
    
    Work around:
    If the filesystem contains multiple
    filesets (even the root filesystem) then check
    if any of them exceeds the defined
    limits and fix this issue.
    Use mmdf and mmlsfileset commands
    for more diagnostic.
    
    Problem trigger:
    One fileset out of multiple filesets for the
    same filesystem ran out of inode space
    
    Symptom:
    Error output/messages
    
    Platforms affected:
    ALL Operating System environments
    
    Functional Area affected:
    System Health
    
    Customer Impact:
    Low
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ31785

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-01

  • Closed date

    2021-04-01

  • Last modified date

    2021-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
02 April 2021