A fix is available
APAR status
Closed as program error.
Error description
The IMS IRM_TIMER has special values which are not durations in milliseconds. Support for these values, 0 and -1, have been added with this APAR. Value 0: Use default values. The default for all RESUME_TPIPE is two seconds. The default for all RESUME_TPIPE non-single ACK is .25 seconds. The value of the TIMEOUT parameter in the IMS Connect TCPIP configuration statement for all others. Value -1 (0xFF): Wait indefinitely. This setting is intended to support the auto option of the asynchronous output function
Local fix
Problem summary
Added handling of IMS IRM_TIMER values 0 and -1 for IMS Callout Handler. The IRM_TIMER has special values which are not durations in milliseconds. Adding the value 0 to use default values: 1. The default for all RESUME_TPIPE is two seconds. 2. The default for all RESUME_TPIPE non-single ACK is .25 seconds. 3. The value of the TIMEOUT parameter in the IMS Connect TCPIP configuration statement for all others. Adding the value -1 (0xFF) to wait indefinitely.
Problem conclusion
Fixed in 2018.4.1.16, 10.0.1.3
Temporary fix
Comments
APAR Information
APAR number
IT35370
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-14
Closed date
2021-03-30
Last modified date
2021-03-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
RA0X PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]
Document Information
Modified date:
29 August 2021