Error description

  • When trying to maximize throughput of their simple RPT 10.0.2
    HTTP test, a customer found that a request which contained a
    substitution from the Sequential Number built-in datasource was
    taking substantially longer to execute than expected.  The
    datasource was configured to be shared across all users
    ("Execute for individual user" was not checked) so that each
    user would get a unique value.  Further testing showed that
    accessing this datasource could take over a 1000 times longer
    than a non-shared Sequential Number datasource (where "Execute
    for individual user" was checked).  It is understandable that
    there would be some increased access time with the shared
    datasource due to the need to coordinate access among the users
    but this degree of increase seems unreasonable, especially since
    the Sequential Number access time is 100s of times larger than
    the time for a shared dataset.
    

Local fix

  • As a workaround, the customer created a dataset with sequential
    numbers and used this, with Open mode set to "Shared (per test
    execution) and Access mode set to Sequential, instead of the
    Sequential Number datasource.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * RPT Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH35726

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-25

  • Closed date

    2021-07-20

  • Last modified date

    2021-07-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

  • RA02 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
05 November 2021