A fix is available
APAR status
Closed as program error.
Error description
GDPS hardware function fails to start, no LOCAL CPC found. BCPII not connected - message ING828I received; message ING825I not received. ING828I GDPS CURRENTLY CANNOT USE THE LOCAL SE CONNECTION also see GTP4 AOFA0099 STATCOM CEC4 STATUS(NOT_CONNECTED) CPCSNAME(IBM390PS.GR15CEC4) DEST() LASTS() TSTIME(210303173424) GDPS/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Z System Automation V4R2 or * * V4R1 using the hardware automation functions * * of the product to monitor and control IBM Z. * * All GDPS users using System Automation V4R2 * * or V4R1 to monitor and control IBM Z. * * * **************************************************************** * PROBLEM DESCRIPTION: At System Automation start or * * configuration refresh time, in case * * processor connections of type INTERNAL * * are defined, the local CPC support * * element connection is evaluated and * * tested. * * * * The local processor connection detect * * logic incorrectly may return CPCnames * * as local, which are not requested to be * * veryfied for local connectivity. * * In GDPS environments, message ING828I * * is issued for the wrong reason and GDPS * * does not start its SA-BCPii usage. * **************************************************************** Message ING828I is incorrectly issued because of a wrong local CPC detection returning incorrect CPCname as the local.
Problem conclusion
- ReXX macro AOFC0172 was changed. The wrong checking was corrected to return only the CPCnames as local if that is true and its the CPCname to be checked. - The following ReXX modules have been rebuild in order to pick up the changed AOFC0172 macro: INGRX806, INGRX810, INGRX815, and INGRX830.
Temporary fix
Comments
APAR Information
APAR number
OA61006
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-04
Closed date
2021-03-15
Last modified date
2021-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ05056 UJ05057
Modules/Macros
INGRX806 INGRX809 INGRX810 INGRX815 INGRX830
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.