A fix is available
APAR status
Closed as program error.
Error description
Customer is performing LOAD processing an using a CONTROL file allocated as a temporary data set via a DD statement. The file extends to secondary volumes and the process abends with: CEE3250C The system or user abend SA78 R=00000010 was issued. From compile unit IBDCB at entry point IBDCB at compile unit offset +00000F5C at entry offset +000002CC at address 20B7006C. Traceback: DSA Entry E Offset Statement Load Mod 1 CEEHDSP +00004A4C CEEPLPKA 2 IBDCB +000002CC FOPIO 3 XFMClose +0000B624 4218 FOPZFMMN 4 XFMOpen +000428C2 3732 FOPZFMMN 5 FOPMDBMN_dynamn +00001BEC 310 FOPMDBMN 6 DB2LoadStatement +0001227E 2722 FOPMMUTL 7 FOPMMUTL_dynamn +000092C2 679 FOPMMUTL 8 main +00008FEC 1079 FOPMAIN 9 EDCZMINV +000000C2 CEEEV003 10 CEEBBEXT +000001C6 CEEPLPKA
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Optim customers executing processes using a * * CONTROL file. * **************************************************************** * PROBLEM DESCRIPTION: Optim may abend SA78. * **************************************************************** Processing does not account for multi-volume temporary data sets used as CONTROL files.
Problem conclusion
Optim processing has been corrected. Note that there is a limit of maximum 5 volumes which may be occupied by/allocated to a temporary CONTROL data set. The following error will be presented in the Process Report when the maximum has been exceeded: "Control File Is Not Built or has Invalid Format or Allocation"
Temporary fix
Comments
APAR Information
APAR number
PH35030
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-03
Closed date
2021-03-11
Last modified date
2021-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP09B FOP0AB FOP9APIM FOPCFPMN FOPHSTM FOPMAIN FOPMAMAI FOPMDPRC FOPOMN FOPRS3 FOPZFMMN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI74392
UP21/04/01 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"B70"}]
Document Information
Modified date:
03 April 2021