APAR status
Closed as program error.
Error description
AFM gateway node asserts if the home is not responding and multiple threads are trying to read the same file.
Local fix
Use undocumented config option "mmfsadm afm readbypass -1" at the gateway node.
Problem summary
AFM gateway node asserts if the home is not responding and multiple threads are trying to read the same file.
Problem conclusion
Benefits of the solution: No more assert Work around: Use undocumented config option "mmfsadm afm readbypass -1" at the gateway node. Problem trigger: Reading same file from multiple threads when the home is not responding Symptom: Crash Platforms affected: All Linux OS environments Functional Area affected: AFM Customer Impact: HiPER
Temporary fix