Notification
Risk classification
HIPER (High Impact and/or Pervasive)
Risk categories
Data Loss
Affected Domain
All DS8900F below R9.1 SP2 – 89.12.8.0
Abstract
Potential DS8900F Data Loss during a system power outage, without graceful shutdown.
Description
A very small timing window has been identified where volatile write cache may not be preserved during a sudden power down of the DS8900F system (system power outage without graceful shutdown).
Recommended Action
Potential Mitigation:
Ensure DS8900F system power cords are properly connected to fully redundant UPS-protected power.
Fix:
Update to R9.1 SP2 – 89.12.8.0 or higher.
Note: This update will require approximately 1 additional hour, per processor node, than the usual bundle update.
Reference ID
350299
Date first published
08 March 2021
[{"Risk Classification":"HIPER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHGBU","label":"IBM DS8900F"},"ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"}]