APAR status
Closed as program error.
Error description
SetAttr operation on renamed object can get requeued forever during AFM replication to the COS backend.
Local fix
Problem summary
SetAttr operation on renamed object can get requeued forever during AFM replication to the COS backend.
Problem conclusion
Benefits of the solution: Replication from GPFS cluster to COS servers through AFM can proceed uninterrupted. Work around: None available. Problem trigger: 1) Create newObject1 2) SetXattr/SetAttr on newObject1 3) Create newObject2 4) SetXattr/SetAttr on newObject2 5) Rename newObject1 as newObject2 Symptom: Unexpected Results/Behavior Platforms affected: ALL Linux OS environments (AFM Gateway nodes) Functional Area affected: AFM Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ30685
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-09
Closed date
2021-02-09
Last modified date
2021-02-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
10 February 2021