A fix is available
APAR status
Closed as new function.
Error description
This APAR improves performance when LIU runs under IMS Administration Tool.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the DBD/PSB/ACB Reversal, the * * Catalog Manager, the Advanced ACBGEN utility * * and LIU under the IBM IMS Administration * * Tool. * **************************************************************** * PROBLEM DESCRIPTION: This APAR provides new option keyword * * for decoding condition that specifies * * whether to refer to a PSB-type ACB when * * LIU utilities decodes an ACB for DEDB * * or MSDB. When the target library has * * many members, it can be time-consuming * * to obtain these values. User can select * * whether the utility skips this process. * * * * This APAR also fixes the problem of the * * Advanced ACBGEN when large number of * * members are specified in the SYSIN * * statement. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR provides new option keyword, REFER_PSB=YES|NO, for decoding condition that specifies whether to refer to a PSB-type ACB when the utility decodes an ACB for DEDB or MSDB. When the DBD/PSB/ACB Reversal utility or Catalog Manager utility decodes an ACB for a DEDB or MSDB, a PSB-type ACB that references the ACB is used for obtaining the DBD VERSION or EXIT parameter value because DBD-type ACB does not have this value. When the target library has many members, it can be time-consuming to obtain these values. You can specify whether the utility skips this process to obtain these values. When the utility skips this process to obtain these parameter values, warning message FABN0077W is issued in the decoded source and the SYSOUT dataset or the message report. The DBD/PSB/ACB Reversal utility and Catalog Manager utility can use this option. The default value is YES and the utility supplies these values from PSB-type ACB. This APAR also fixes the Advanced ACBGEN to process all of the members specified in the SYSIN statement even when a large number of members are specified in the SYSIN statement. The Advanced ACBGEN missed to store all of the specified members if a large number of members are specified in the SYSIN statement. This APAR fixes to process all of the members specified in the SYSIN statement. The digit number RCD# that are written in the CONTENTS OF "SYSIN " CONTROL STATEMENT DATASET of the INPUT SPECIFICATIONS report has been increased by one digit. This APAR also improves the performance of the function for IMS Administration Tool. ======================== = DOCUMENTATION CHANGE = ======================== The documentation "IBM IMS Library Integrity Utilities for z/OS V2R2, User's Guide (SC19-3979-05)" is changed. For all the documentation changes, see documentation updates on IMS Tools library site. https://www.ibm.com/support/pages/node/712955#imsliu-lib
Problem conclusion
The following modules and macros have been modified. FABNPDBD, FABNREAD, FABNTGEN, FABQSYSI, FABXAAC0, FABXAAC1, FABXACAD, FABXACA0, FABXATY0, FABXCAP4, FABXCAST, FABXCATM, FABXCBLD, FABXCC00, FABXCTB0, FABXSTMD, FABXWMT, FABNSDT, FABNWORK, FABXACT, FABXCTB
Temporary fix
Comments
APAR Information
APAR number
PH34243
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2021-02-08
Closed date
2021-03-03
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74232
Modules/Macros
FABNPDBD FABNREAD FABNTGEN FABQSYSI FABXAAC0 FABXAAC1 FABXACA0 FABXACAD FABXATY0 FABXCAP4 FABXCAST FABXCATM FABXCBLD FABXCC00 FABXCTB0 FABXSTMD FABXWMT
| SC19397905 |
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI74232
UP21/03/05 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
08 September 2022