IBM Support

IJ30711: GETTING TIMEOUT ERRORS WHILE TRYING TO FIX A METER READING, DUE TO SITE ID.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • STEPS TO REPRODUCE:
    
    Steps to replicate
    1.Go To Asset
    Application
    2. Create Asset "1001" and add ?FUEL-G? meter from
    the Meters tab
    3. From more actions, Enter
    Meter Reading> add 3
    readings
    4. Go to user Default Information change Default
    insert site to Denver.
    5. Recreate steps from 1 to 3, use the
    same assetnum?1001?
    6.From more actions Mange Meter Reading
    History. modify reading.
    RESULTS
    The query below is causing
    proformas issue, as when the run it against the backends db it
    returns no result
    Select * from meterreading where metername=
    'CYCLES' and inheritedfromasset= '425755' and
    readingdate>TO_TIMESTAMP ('2020-10-04 00:00:00.000' ,
    'YYYY-MM-DD HH24:MI:SS.FF') and readingdate<=TO_TIMESTAMP
    ('2020-11-02 00:00:00.000' , 'YYYY-MM-DD HH24:MI:SS.FF') and
    assetnum!= '425755' order by assetnum,readingdate
    asc
    
    
    
    REPORTED IN VERSION:
    
    Maximo Asset Management 7.6.1.1
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo users                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * METERREADING SQL query causing performance issue. Needs to   *
    * include SITEID.                                              *
    ****************************************************************
    STEPS TO REPRODUCE:
    1.Go To Asset
     Application
     2. Create Asset "1001" and add ?FUEL-G? meter from
     the Meters tab
     3. From more actions, Enter
     Meter Reading> add 3
     readings
     4. Go to user Default Information change Default
     insert site to Denver.
     5. Recreate steps from 1 to 3, use the
     same assetnum?1001?
     6.From more actions Mange Meter Reading
     History. modify reading.
     RESULTS
     The query below is causing
     proformas issue, as when the run it against the backends db it
     returns no result
     Select * from meterreading where metername=
     'CYCLES' and inheritedfromasset= '425755' and
     readingdate>TO_TIMESTAMP ('2020-10-04 00:00:00.000' ,
     'YYYY-MM-DD HH24:MI:SS.FF') and readingdate<=TO_TIMESTAMP
     ('2020-11-02 00:00:00.000' , 'YYYY-MM-DD HH24:MI:SS.FF') and
     assetnum!= '425755' order by assetnum,readingdate
     asc
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package: Release 7.6.1.3 of Base Services
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ30711

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-02-04

  • Closed date

    2021-05-28

  • Last modified date

    2021-05-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761"}]

Document Information

Modified date:
29 May 2021