Error description

  • The administrator is unable to change the page pool setting
    on the GNR recovery group server. The problem is seen
    only on recovery groups not managed by mmvdisk.
    The mmchconfig command will fail, and the
    following error message:
    The --force-rg-server flag must be used to change the pagepool
    

Local fix

Problem summary

  • The administrator is unable to change the page pool setting
    on the GNR recovery group server. The problem is seen
    only on recovery groups not managed by mmvdisk.
    The mmchconfig command will fail, and the
    following error message:
    The --force-rg-server flag must be used to change the pagepool
    

Problem conclusion

  • Benefits of the solution:
    Code change allows the --force-rg-server option to
    successfully bypass the GNR pagepool checks
    
    Work Around:
    None
    
    Problem trigger:
    mmchconfig pagepool=<newValue> on a GNR server
    not administered by the mmvdisk command set.
    
    Symptom:
    Error output/message
    Unexpected Results/Behavior
    
    Platforms affected:
    ALL Linux OS environments
    
    Functional Area affected:
    ESS/GNR
    Customer Impact:
    Suggested
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ30493

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-27

  • Closed date

    2021-01-27

  • Last modified date

    2021-01-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following: